Trane refrigerant piping software

Its extremeweather tested, while packed with innovative trane technology. Refrigerant type 4 r410a trane product type w split heat pump t split cooling product family. Accuload and accucomm is an easy, fast and accurate computer software program for calculating heat loss. Engineering toolbox provides nine calculation tools to simplify hvac design and service tasks. Leed v4 ea enhanced refrigerant management credit calculator. Download refrigeration piping design software for free.

Software building controls intl sales tools spectrum system analyzer topss trace 3d plus trace 700 family trane acoustics program trane engineers toolbox trane pipe designer varitrane duct designer. Most common refrigerant types are built into the software, including r22, r410a, r4a, r404a, r407c, r502, r507, and ammonia. Variable refrigerant flow vrf systems consist of outdoor units connected to multiple indoor units via refrigerant piping to provide cooling and heating to individual zones. First off, a good system begins with a little planning. This particular clinic introduces the reader to refrigerant piping. Office tools downloads saravel refrigerant pipe sizing by saravel and many more programs. As equipment evolves, so must piping practices split systems and interconnecting refrigerant lines the efficiency and reliability of an r22, split airconditioning system hinges largely on the piping that connects the refrigerant condensing and airhandling sides of the system. As equipment evolves, so must piping practices trane. Use the program to determine required pipe sizes, find the critical path for proper pump sizing, and calculate pressure drops through valvesfittings or from elevation changes. Elite software 30 hvac software programs for all aspects of hvac, plumbing and electrical system design. A general knowledge of piping practices is required to make an intelligent choice. Where can i find the maximum lineset lengths and correct sizes allowed for this unit. Trane split system cooling product data xb14 1 12 bay area.

Sep 03, 2018 refrigerant piping insulation has historically escaped the scrutiny that it has found itself under recently in some jurisdictions. Application guide 32300903 general information the four prime considerations in designing a refrigerant piping system are. Use the york comfort cooling piping software to determine liquid line. You get cost savings, comfort and control to improve life in a wide variety of building types. Someone told me there is a piping calculator from trane to figure it out but i have been unable to find it. You can get a cd by calling pretty incredible, 5023686555. Refrigerant piping insulation has historically escaped the scrutiny that it has found itself under recently in some jurisdictions. Application guide refrigerant piping manual for small. Vaidation codes are provided only if you have a cd with a serial number displayed on the cd face. The outdoor units can modulate capacity based on the requirements of the individual zones, thus saving energy by not always running at 100% capacity and improving occupant. Two pipe system uses less space, with faster installation and.

I have a 5 ton xl 16 i heat pump with a tam060c air handler r410a that i will be installing. The piping design of any air conditioning system will affect the performance, reliability, and applied cost of that system. Tracer ch530 techview software download tranecommercial. The cad mode allows for users to incorporate autocad into the software for easy customization. These tasks include duct sizing, wire sizing, three way coil interpolation, mixed air and state point psychrometrics, fan curve and cost analysis, ufactor calculations, natural gas pipe sizing, refrigeration line sizing, general pipe sizing, hotchilled water pipe analysis and the. The trane air conditioning clinic series is one means of knowledge sharing. Trane has a policy of continuous product and product data improvement and it reserves the right to. Refrigerant piping design check list the first step in refrigerant piping design is to gather product and jobsite information. How this information is used will be explained throughout the rest of this guide. Mechanical specifications general the 4twx8 is fully charged from the factory for matched indoor section and up to 15 feet of piping. Vrf piping design software variable refrigerant flow air. A contaminated refrigerant can damage the integral components of a cooling unit, affect.

The elite software hvac tools program allows the quick calculation of common hvac design tasks. By having the refrigeration system close to the refrigeration demand, your installation and operating costs are less, due to a reduced refrigerant charge, less refrigerant piping and fewer braze joints that reduce refrigerant leaks. Properties of air calculates all properties of moist or dry air at normal hvac conditions using one state point. Downloads adtek acca manual j manual d manual s hvac heat.

The design of refrigerant piping systems involves capacity and efficiency, reliability, oil management, refrigerant charge, sound level, liquid refrigerant control, modulation effectiveness and cost. Trane split system cooling product and performance data. Refrigerant type 2 r22 4 r410a trane product type w split heat pump t split cooling product family z leadership two stage x leadership r replacementretail. Designing the right hvac system for a buildings purpose is a science. Page 8 installers guide trane a business of american standard companies. Trane refrigerant line sizing software part of the engineering toolbox. Refrigerant piping a trane air conditioning clinic. Refrigerant piping design goals the liquid line must prevent. Individual programs assist in peak load calcuation, system design, building energy modeling, lifecycle cost analysis, and refrigerant piping design. The most popular version among the program users is 1. Application guide refrigerant piping manual for small split. Use the program to determine required pipe sizes, find the critical path for proper.

The refrigerant piping design program determines the minimum pipe size required to deliver refrigerant between the compressor, condenser and evaporator within specified pressure loss limits. This document should serve as a guideline for proper splitsystem piping installation. With energy codes getting stricter during each code cycle, and some large lawsuits related to refrigerant piping being. Saravel refrigerant pipe sizing free download windows version. The latest version of the engineering toolbox is an intuitive redesign that provides a consolidated input and output view, an advanced report generation method for comparing multiple datasets and additional refrigerant and fluid types. The software will generate an estimated quantity of refrigerant that you will be required to supply to meet the required capacity of the system. In keeping with industry standards, the refrigerant piping design program. Refrigerant line sizing allows selection of sizes of the interconnecting piping in a refrigerant system including suction line, discharge line and liquid line for a. This particular clinic introduces the concept of refrigeration compressors. Vrf technology is a popular choice for a variety of building sizes and uses by offering higher energy efficiency, smaller footprints and greater flexibility.

Introduction an application is considered long line, when the refrigerant level in the system requires the use of accessories to maintain. All resources trial software documentation full version updates. The latest version of the engineering toolbox is an intuitive redesign that provides a consolidated input and output view, an advanced report generation method for comparing multiple datasets and additional refrigerant. Caution if using existing refrigerant lines make certain that all. The most popular version of this product among our users is 2. This mode features automatic calculation of refrigerant piping. Unit sections can be shipped split or split in the field without losing the factory charge resulting in no field brazing and a total installed cost. Guide, ssapg006en or refrigerant piping software program, 32331203 or latest revision. Hvac design software download center trane commercial.

Among a service techs many responsibilities is to pipe together refrigeration system components. Trane product data split system heat pump xl18i 4wtx8. Locate and install indoor coil or air handler in accordance with instruction included with that unit. Piping application data sheet introduction installation of residential and commercial splitsystems should be performed by qualified service technicians with proper training in the installation, service and repair of these units. Samsungs dvmpro system design software is an advanced design selection tool that helps users select the most appropriate vrf or chiller equipment based on the information provided. The trane pipe designer streamlines the pipe design process. Trane refrigerant piping software and downloads piping. Trane installers guide condensing units 4ttr3018060.

The program will also size vertical risers so that oil entrainment is assured. Dec 06, 2017 the software will generate an estimated quantity of refrigerant that you will be required to supply to meet the required capacity of the system. Refrigerant type 2 r22 4 r410a trane product type w split heat pump t split cooling product family. Product information model number of unit components condensing section, evaporator, etc. Split system cooling product data national air warehouse. Trane product data split system air conditioner 3phase 4tta4. Trane xr series 34,500 btuh central air conditioner 4ttr3036hn. Split system refrigerant piping guide r410a refrigerant subject to change without notice. Liquid line 1f to 2f, 300 fpm suction line 2f, 750 fpm horizontal, 1500 fpm suction riser, 4000 fpm. Doing our best for our customers is the bare minimum for the trane team. Trane design software packages offer all of the options and modeling.

Refrigerant piping one of the fundamental series a publication of trane. A system reliability b oil return c friction losses pressure drop d cost a the piping system can affect system reliability in a number of ways. What could possibly be such a big deal with plain old boring refrigerant piping insulation. The amount of refrigerant charge should be indicated in the report. This free software is an intellectual property of saravel. Clipping is a handy way to collect important slides you want to go back to later. It also comes with a seer that meets new federal regulations. Trane 47,000 btuh central air conditioner 4ttr4048la. Efficient performance the xr14 ac system has a seer rating of up to 16. D h w unit dimensions and weight models h x d x w in weight lb 4ttr7024a 41 x 34 x 37 240 4ttr7036a 45 x 34 x 37 245 4ttr7048a 45 x 34 x 37 254. These calculators include software to calculate your potential leed compliance. Application and design and fabrication guidelines l9 february.

Nov 26, 2002 good piping practices are essential to guarantee a long life and minimal maintenance for refrigeration and freezer equipment. Aug 29, 2001 among a service techs many responsibilities is to pipe together refrigeration system components. Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, fifteen 15 feet of tested connecting line, and the smallest. Downloads adtek acca manual j manual d manual s hvac.

All oil must be captured and recycled or disposed of in accordance with national, state, and local. Variable refrigerant flow vrf technology is taking the hvac industry by storm. These programs are tailored to increase productivity and accuracy, improve analysis capabilities and job documentation, and add a level of marketability to a designers estimates. Hsym analyze chilled and hot water hvac piping systems. A trusted partner like trane can help you understand the benefits of vrf technology, decide if a vrf system is the right fit for your project and help you design a complete system for your needs. Unit dimensions and weight models h x d x w in weight lb 4ttr3018h 29 x 26 x 29 3. Trane outdoor condensing units are factory charged with the system charge. Split system refrigerant piping guide united coolair. Cooling quietly and affordably, the xr turns your home into a haven. View and download trane 2ttb3 installers manual online. Contents period one refrigerant piping requirements 1 period two suction line. A trusted partner like trane can help you understand the benefits of vrf technology, decide if a vrf system. Trane refrigerant piping length where can i find the maximum lineset lengths and correct sizes allowed for this unit.

Trane xr14 series 47,000 btuh central air conditioner 4ttr4048la. This improves life and reduces audible noise in many operating conditions. General piping recommendations and refrigerant line. This pc program is suitable for 32bit versions of windows xpvista7810.

The many benefits of trane advantage vrf variable refrigerant systems trane advantage vrf systems offer a full range of benefits that few other systems can matchand classleading efficiency that no other vrf system can beat. Long line applications guideline r 410a split systems. Trane application guide retrofit guidelines replacing. With the wider availability and use of reclaimed and recycled refrigerants, the trane lab helps users of the refrigerants evaluate their quality. Gc on the job wants to put the units away from the house. Good piping practices are essential to guarantee a long life and minimal maintenance for refrigeration and freezer equipment. The indoor coil may require removal in order to purge all existing oil from the coil. Now customize the name of a clipboard to store your clips. When piping a system together, a technician must decide which pipe size to use its not always as simple as it may appear. Conducting comprehensive load analyses, considering air supply requirements, weather conditions, determining optimum hvac system, piping and duct configurations, and then applying those considerations to specifications are all critical to high performance building design. Air conditioning clinic refrigeration compressors one of the. Trane outdoor condensing units are factory charged with the system charge required for the outdoor condensing.

The outdoor unit should come precharged with an amount for the system excluding the piping. Holes must be made in the structure to run refrigerant lines. Hvac system design software carrier commercial systems. Air conditioning clinic refrigerant piping one of the. Refrigerant line sizing allows selection of sizes of the interconnecting piping in a refrigerant system including suction line, discharge line and liquid line for a given system.